Cable Cross -Section
Fiber: G.G652D, G.657A1, G.657A2
Feature:
- Smaller diameter
- Frees up capital to expand network and client base
- Network design flexibility
- 5/3.5mm microduct suitable
- Easy to upgrade
- Greater blowing distance
- Fiber: G.G652D, G.657A1, G.657A2
Standards:
- Unless otherwise specified in this specification, all requirements shall be mainly in accordance with the following standard specifications.
- Optical fiber:ITU-T G.651、G.652、G.655、G.657 IEC 60793-2-10、IEC 60793-2-50
- Optical Cable:IEC 60794-1-2、IEC 60794-5
- Note: It is recommended that the structure of 2 fibers unit consist of 2 filled fibers, for it is proved that this structure is better in the blowing performance and the fiber separability than that of one with zero or one filled fiber
Specification:
Fiber count (F) |
Nominal diameter (mm) |
Nominal weight (kg/km) |
Min. bend radius (mm) |
Temperature (℃) |
2 | 1.15±0.05 | 1 | 50 | -30 to +60 |
4 | 1.15±0.05 | 1 | 50 | |
6 | 1.35±0.05 | 1.3 | 60 | |
8 | 1.50±0.05 | 1.8 | 80 | |
12 | 1.65±0.05 | 2.2 | 80 |
Blowing Test:
Fiber count (F) |
Blowing machine | Suitable microduct (mm) |
Blowing pressure (bar) |
Blowing distance (m) |
Blowing time (min) |
2 | PLUMETTAZ UM25 ERICSSON F CATWAY FBT-1.1 |
3/2.1 or 5/3.5 | 7/10 | 500/1000 | 10/18 |
4 | 3/2.1 or 5/3.5 | 500/1000 | 10/18 | ||
6 | 5/3.5 | 500/1000 | 10/18 | ||
8 | 5/3.6 | 500/1000 | 13/18 | ||
12 | 5/3.5 | 500/800 | 15/20 |
Attenuation:
fiber Type | SM G.652D、G.655、G.657 | MM 62.5/125 |
Attenuation | 0.38dB/km max @1310nm 0.26dB/km max @1550nm |
3.5dB/km max @850nm 1.5dB/km max @1300nm |
Mechanical Performance:
Test | Standard | Parameters | Test Results |
Tension | IEC 60794-1-2-E1 | Load is 1×W | fiber strain ≤0.4% at MAX Additional attenuation ≤0.05dB fiber strain ≤0.05% after test |
Bend | IEC 60794-1-2-E11A | Diam 40mm×3turns 5 cycles at 20℃ |
Additional attenuation ≤0.05dB,after test |
Crush | IEC 60794-1-2-E3 | 100 N, 60s | Additional attenuation ≤0.05dB,after test |
All optical testing proceeded at 1550 nm |
Environment Performance:
Test | Standard | Parameters | Test Results |
Temperature Cycle | IEC 60794-1-2-F1 | +20°C, -40°C, +60°C, (3 cycles) |
Absolute attenuation ≤0.5dB/km,during test Additional attenuation ≤0.1dB/km, during and after test |
Water Soak | IEC 60794-5 | 1000 hours in water, 18℃~22℃ |
(Test after temp cycle) ≤0.07dB/km Change compared to start value |
Damp Heat Cycle | IEC 60068-2-38 | 25°C, 65°C, 25°C, 65°C, 25°C, -10°C, 25°C |
Absolute attenuation ≤0.5dB/km,during test Additional attenuation ≤0.1dB/km, during and after test |
All optical testing proceeded at 1550 nm |
Packing and Marking:
- Each single length of cable shall be reeled on Fumigated Wooden Drum
- Covered by plastic buffer sheet
- Sealed by strong wooden battens
- At least 1 m of inside end of cable will be reserved for testing.
- Drum length: Standard drum length is 3,000m±2%; as required
- 5.2 Drum Marking(can according to the requirement in the technical specification) Manufacturer name;
- Manufacturing year and month Roll—direction arrow;
- Drum length; Gross/net weight;
Packaging and Shipping: