Cable Cross -Section:
Fiber Type:
G652D; G655C; 657A1; 50/125; 62.5/125; OM3; OM4 As Options
Application:
Aerial/Duct/Outdoor
Main Feature:
1. Suitable for use on distribution and high voltage transmission lines with mini spans or self-supporting installation for telecommunication ;
2. Track -Resistant outer jacket available for the high voltage;
3. Line where space potentials up to 35KV;
4. Gel-Filled buffer tubes are S-Z stranded;
5. Instead of Aramid yarn or glass yarn,there is no support or messenger wire required. Aramid yarn is used as the strength member to assure the tensile and strain performance for mini span (usually below 150meters);
6. The fiber counts from 2-288 fibers.
Temperature Rage:
Operating :-40℃ to +70℃
Storage :-40℃ to +70℃
Standards: Comply with standard YD/T 769-201
Structure and Technical Specifications GYFTY
Fiber Count | NominalDiameter (mm) | NominalWeight (kg/km) | Max Fiber Per Tube | Max No. of (Tubes+fillers) | Allowable Tensile Load (N) | Allowable Crush Resistance (N/100mm) | ||
Short Term | Long Term | Short Term | Long Term | |||||
2~36 | 10.2 | 85 | 6 | 6 | 1500 | 600 | 1000 | 300 |
38~72 | 11.1 | 100 | 12 | 6 | 1500 | 600 | 1000 | 300 |
74~96 | 12.6 | 130 | 12 | 8 | 1500 | 600 | 1000 | 300 |
98~120 | 14.1 | 162 | 12 | 10 | 1500 | 600 | 1000 | 300 |
122~144 | 15.9 | 204 | 12 | 12 | 1800 | 600 | 1000 | 300 |
146~216 | 15.9 | 205 | 12 | 18(2 layers) | 2200 | 600 | 1000 | 300 |
>144 | Available upon customer request |
Structure and Technical Specifications GYFTY-G (Yarn)
Fiber Count | NominalDiameter (mm) | NominalWeight (kg/km) | Max Fiber Per Tube | Max No. of (Tubes+fillers) | Allowable Tensile Load (N) | Allowable Crush Resistance (N/100mm) | ||
Short Term | Long Term | Short Term | Long Term | |||||
2~36 | 10.2 | 85 | 6 | 6 | 1500 | 600 | 1000 | 300 |
38~72 | 11.1 | 100 | 12 | 6 | 1500 | 600 | 1000 | 300 |
74~96 | 12.6 | 130 | 12 | 8 | 1500 | 600 | 1000 | 300 |
98~120 | 14.1 | 162 | 12 | 10 | 1500 | 600 | 1000 | 300 |
122~144 | 15.9 | 204 | 12 | 12 | 1800 | 600 | 1000 | 300 |
146~216 | 15.9 | 205 | 12 | 18(2 layers) | 2200 | 600 | 1000 | 300 |
>144 | Available upon customer request |
Note : This datasheet can only be a reference, but not a supplement to the contract. Please contact our sales people for more detailed information.
Duct Fiber Cable Solution:
Packing and Marking:
- Each single length of cable shall be reeled on Fumigated Wooden Drum
- Covered by plastic buffer sheet
- Sealed by strong wooden battens
- At least 1 m of inside end of cable will be reserved for testing.
- Drum length: Standard drum length is 3,000m±2%; as required
- 5.2 Drum Marking(can according to the requirement in the technical specification) Manufacturer name;
- Manufacturing year and month Roll—direction arrow;
- Drum length; Gross/net weight;
Packaging and Shipping: